Single Phase (1PH) Load
REVO S 1PH Thyristor Power Controller
- From 30 up to 700A
- Max. voltage 480V or 600V AC as option
- Load type: Resistance, IR Lamp long and medium waveform
- Inputs: SSR Std, 0:10V, 4:20mA and Heather Break alarm are options
- Firing mode: Zero Crossing, Burst Firing available with analogue input only
REVO M 1PH Thyristor Power Controller
- From 30 up to 700A
- Max. voltage 480V or 600V AC as option
- (690V available on units > 280A)
- Load type: Resistance, IR Lamp short waveform and SiC element.
- Inputs: SSR, 0:10V, 4:20mA, 10KPot and Communication Std.
- Heather Break is available as an option.
- Firing mode: Burst Firing, Single Cycle & Phase Angle as standard

REVO CL Thyristor Power Controller
- From 30 up to 700A
- Max. voltage 480V or 600V AC as option
- (690V available on units > 280A)
- Load type: Inductive Load, Transformer, UV Lamp and MoSi2 element.
- Inputs: SSR, 0:10V, 4:20mA, 10KPot and Communication Std.
- Firing mode: Delay Triggering + Burst Firing (DT), Phase Angle (PA) or Soft Start + Phase Angle (S+PA); Current Limit is available with Phase Angle

Multidrive 1PH Thyristor Power Controller
- From 850 up to 2700A
- Max. voltage 480V, 600V or 690V AC as option
- Load type: Inductive Load, Transformer and MoSi2 element.
- Inputs: SSR, 0:10V, 4:20mA, 10KPot and Communication Std.
- Firing mode: Delay Triggering + Burst Firing (DT), Phase Angle (PA) or Soft Start + Phase Angle (S+PA); Current Limit is available with Phase Angle

REVO TC 1PH Temperature and Power Controller
- Suitable for Normal Resistance load types
- From 30A to 210A
- Max. voltage 480V, 600Vac
- Load type: Resistance
- Inputs: Pt100, Thermo Couple, 0:10V, 4:20mA
- Heather Break alarm options
- Firing mode: Zero Crossing

REVO PC Reduce Power Peaks and Maximise your Savings
- Suitable for Normal Resistance and IR Lamp
- To be used with REVO S and REVO Sx
- Firing Mode: SC, HC and Dynamic Burst Firing
- Reduce Peak of Power and let you save Energy
- Modbus RTU, Profibus, Profinet, Modbus TCP, Ethernet IP and other fieldbus
- Heather Break Alarm

CD3000 Series | CD3000S | CD3000M | CD3200 Thyristor Unit
- Premium Series 1-2-3PH
- From 10A to 700A
- Max. voltage 480V, 600Vac
- cUL us is available as an option
- Heather Break alarm options

REVO SSR Long Life Solid State Relay
- Range: 0:62; 0:7; 0:90
- Max. voltage 480V or 600V AC as option
- Load type: Resistance
- Inputs: SSR Std, 0:10V, 4:20mA and Heather Break alarm are options
- Firing mode: Zero Crossing

REVO Sx | Multiple Low Power Solid State Relay
- From 3.5 up to 7A
- Max. voltage 240V or 480V AC as option
- Load type: Resistance, IR Lamp long and medium waveform
- Inputs: SSR Std, Heather Break alarm as an option
- Firing mode: Zero Crossing

REVO SSR ANALOG | 0:10V & 4:20mA Input SSR
- Rating 0:62; 0:74 and 0:90
- Max. voltage 480V or 600V AC as option
- Load type: Resistance, IR Lamp long and medium waveform
- Inputs: 0:10V, 4:20mA and Heather Break alarm are options
- Firing mode: Burst Firing